null Skip to main content
"New" Money Saving Snow Guard Bundles
See Now
(No reviews yet) Write a Review
SKU: RC2B-Mill-6FT

2 Bar SnoBar Snow Rails for Standing Seam Metal Roofs (6 Foot)

$272.00 - $388.00
Availability:
In Stock
For Panel Type:
Standing Seam Metal Roof With Concealed Fastener
Includes:
Bars, Mounting Clamps and Installation Hardware
Processing Time:
Same or Next Day (Mon-Fri)
Adding to cart… The item has been added

Seam Compatibility

The 2-Bar SnoBar For Extreme Metal Roof Snow Retention

The double-bar snow rail is our standard-duty metal roof snow retention SnoBar system. It features two mill-finish galvanized Gatorshield® coated 1" square SnoBars with aluminum 2-bar brackets that will remain rust-free indefinitely.

The two-bar snow rails are safely and securely fastened to a standing seam panel with the patented aluminum RCT RoofClamp, using stainless steel cup-tipped set screws. The double-bar SnoBar features 2 top loading bars for fast installation. The two-bar SnoBar systems fit about 95% of the standing seam roof profiles. Mill finish 6-foot kits are in stock and shipped fast via ground shipping.  Sample Bar Kits for submittal purposes are available for purchase. .

The Two-Bar Snow Rails are Safe for Standing Seam Metal Roofs

This product is perfect for standing seam metal roofs with its one-piece aluminum clamp featuring three non-penetrating cup-tipped set screws. This continuous 2-bar rail design runs the length of the roof and ensures no risk of damaging roof seams with screws or holes. The double-bar SnoBar prevents rooftop avalanches that can damage gutters, HVAC units, cars, and patios.

The Double-Bar SnoBar Snow Rails Have Great Strength and Durability

Double-bar SnoBar features a Gatorshield® coated bar with great strength and durability. This product features coarsely threaded, super strong "cup tipped" low-torque stainless steel screws that do not bind in the clamp, NOT high torque slippery "round nose" screws that can seize up in the clamp. The product's effectiveness is backed by extensive laboratory and field tests, demonstrating its reliability and performance in real-world conditions.

Two Bar SnoBar With Optional IceStopper

Two Bar SnoBar With Optional IceStopper

2-Bar SnoBar Features:

  • Made in America

  • RCT Seam Mounting Clamp Fits Bulb Seam and T Seam Panels

  • Independent Laboratory and Field-Proven

  • It can be Installed Anytime the Roof is Accessible.

  • Easy installation with Dual Bar "Drop" in Channels.

Double Bar SnoBar is Easy to Install

Exclusive low-torque roof clamps and top-loading 2-bar brackets make this the industry's fastest bar system to install with fewer parts and less labor! 

Custom Designs Available for Double Bar SnoBar Snow Rail

To begin the process, submit the 2-Bar SnoBar Quote Request Form or call us at 1-800-SNOJAX-1 (800-766-5291) with any questions.

Two-Bar SnoBar Submittal Documents

Two-Bar SnoBar ColorBar Specification Sheet

Two-Bar SnoBar Cut Sheet

2-Bar SnoBar ColorBar RCB-2 Clamp Compatibility

2-Bar SnoBar Price Quote Request

Two-Bar SnoBar Installation Instructions

SnoBar Warranty

Standing Seam 2-Bar SnoBar Spacing Guide

2 Bar SnoBar Important Disclaimer:

This snow retention system is not designed to be installed in isolated areas such as just over doorways, stack pipes, chimneys, or partial roof sections. Upper roofs, if any, must not be allowed to shed snow and ice onto lower roof areas where this product is being used. All upper roof areas must have a snow retention system in place before using this product on lower roof areas. Always obtain a manufacturer's quantity and spacing recommendation before purchasing and installing this product. If this system is not used as per the manufacturer's recommendation, severe roof panel damage, personal injury, and/or death may occur.

The following warranty is made in lieu of all other warranties expressed or implied. Recommendations for proper use of the product are based on tests believed to be reliable. Any goods proven to be defective due to materials will be replaced, or purchase price refunded, but in no event shall the manufacturer be responsible for damages in excess of the purchase price. User shall determine the suitability of the product for its intended use and assumes all risks of its use or handling. 1. All loads incurred by the SnoBar will be transferred to the panels. Therefore, proper panel attachment to substrate/structure is necessary to prevent roof panels from sliding under snow load. New and existing structures must be evaluated to insure they can withstand retained snow loads. (In instances where there is an overhang at the eave edge, it is imperative to make sure that the overhang can hold the accumulated loading, otherwise the first row of SnoBar should occur at the bearing wall.) 2. It is not recommended to place the SnoBar System in isolated areas such as doorways, vents and partial roof areas. Please call for special design considerations in those areas. 3. Consider whether your roof system and/or substrates (felts or membranes) run the risk of ice damming with the addition of this type of system. 4. The SnoBar Clamp System requires the roof panel to be a min. of 24 GA. steel and have a seam height of at least 1". Clamp spacing cannot exceed 24"O.C. Clamp spacing varies dependign on seam spacing (12" o.c. up to 42" o.c). Clamps should be placed at every seam, so that the load is distributed evenly to every roof panel. It is not recommended to use a clamp type system when the roof uses a seperate seam cover or batten. 5. The U-Bracket System requires a purlin or structural support beneath it to mount to. 6. No snow retention system is capable of retaining 100% of snow and ice from falling off the roof. 7. Designer/Arhitect, Installer, or Owner of the project should have knowledge of the local snow loads, climatic conditions, roof slope, roof orientation, and roof design prior to installing SnoBar. 8. After considering the above factors, the determine lineal feet of SnoBar required is based on length of panels, roof slope, snow loading and areas needing protection from falling snow. (Call SnoBlox-SnoJax for clamp and bar loading values.) 9. It is the sole responsibility fo the Designer/Architect, Installer, or Owner to assess the suitability of using the SnoBar System based on the above design considerations. SnoBlox-SnoJax or any or its subsidiaries, or Riddell & Company, Inc and Action Manufacturing are under no liability if failure occurs from improper installation, improper set screw torque, improper panel attachment, improper roof system installation, improper use of the SnoBar system or under designed system placement of the SnoBar system. This is a special-order item, thus All Sales are Final. Sorry, no returns accepted.
SnoBar 2-Bar Snow Retention System for Metal Roofs

About SnoBar-ColorBar

In 1992, Don Drew and Dick Riddell invented SnoBar, the original standing seam-mounted snow rail, earning a patent the following year. The first version, Sno Horse, was installed by Jim Huff at Denver International Airport in 1992. Inspired by office desk name plates, he ingeniously created an aluminum bar with a channel that could accept a strip of colored metal in its face. This design evolved into ColorBar, featuring rapid installation with patented drop-in clamps. Roof clamps, available in stainless steel or aluminum, secure the bar to standing seam metal roofs, making SnoBar the longest-standing snow rail system. There is a SnoBar and ColorBar snow retention system for every sloped roof prone to snow slides. Both snow rails can be powder-coated to match your metal roof.