null Skip to main content

Economical 6 Foot SnoBar and ColorBar Snow Rail Kits

See Now

Snow Guards for Aluform Systeme

Snow guards for Aluform Systeme roofing panels help manage the sudden movement of rooftop snow and ice above entrances, walkways, parking areas, landscaping, equipment, and other vulnerable locations. The correct SnoBlox-Snojax solution depends on the exact FALZRIPP standing seam profile, the available flat bonding area, the bulb-shaped seam geometry, and the project conditions.

Compatible Aluform Systeme snow retention options may include adhesive-mounted polycarbonate snow guards, RCB-3 rail assemblies, 2-bar rail systems, and the clamp-on SnoCleat RCT, depending on roof shape, panel condition, and project requirements.
  • FALZRIPP 50/333, 50/429, 65/305, 65/333, 65/400, and 65/500 are concealed-fastener standing seam profiles.
  • Compatible systems attach with adhesive or non-penetrating clamps rather than screws driven through the panels.
  • All six profiles shown accept the listed adhesive-mounted polycarbonate guards when a suitable flat bonding surface is available.
  • The bulb-shaped seams require RoofClamp RCT-based products; standard SnoBar clamps, RoofClamp RC products, and SnoCleat RC are not compatible.
  • Product selection should consider roof curvature, slope, panel width, run length, material softness, striations, ground snow load, and a full-roof layout.
Important: Do not select a snow guard based on appearance alone. Aluform Systeme FALZRIPP profiles use tall, bulb-shaped standing seams, so clamp geometry matters. Standard standing seam clamps and RoofClamp RC products are not suitable for these profiles. Adhesive-mounted guards also require an appropriate flat surface, and curved panels should use compatible clamp-on guards or rail systems instead.

⚡ Aluform Systeme Primary Quick Selection Guide

Use this section for fast profile-level direction. Confirm the exact product fit in the full compatibility chart below.

  • All six FALZRIPP profiles: Compatible with the listed adhesive-mounted polycarbonate guards when the roof has a flat, suitable bonding surface.
  • Bulb-shaped seams: Compatible with RCB-3 SnoBar and ColorBar, 2-bar SnoBar and ColorBar, and SnoCleat RCT.
  • Incompatible clamp styles: Do not use standard SnoBar or ColorBar standing seam systems, RoofClamp RC-based rails, or SnoCleat RC on these profiles.
  • Curved roof warning: Do not use pad-style adhesive guards where panel curvature prevents the base from sitting flat.

About Aluform Systeme Roofing Systems

Aluform Systeme manufactures lightweight aluminum roof and facade systems for new construction and renovation projects. Its FALZRIPP standing seam profiles can be formed in very long lengths without transverse laps. They may be produced in straight, curved, convex, concave, or conical configurations. The six profiles covered here combine 50 mm or 65 mm seam heights with coverage widths ranging from 305 mm to 500 mm.

Snow Retention Solutions for Aluform Systeme Roofing

FALZRIPP panels use concealed, non-penetrating fastening that accommodates thermal movement, so compatible snow retention must preserve the panels' weather-resistant design. Adhesive-mounted polycarbonate guards may be used on straight panels with enough flat bonding area. The bulb seam can also accept specific RCT clamp-based guards and rail assemblies. Softer aluminum panels may require additional project-specific precautions and a test fit before a full order.

See our full range of snow guards for metal roofs and use the chart below to confirm which SnoBlox-Snojax products fit each Aluform Systeme panel. “YES” indicates that the product is shown as compatible with that profile. “*YES” identifies adhesive-mounted products that require a straight panel, a suitable flat mounting surface, proper preparation, and correct adhesive application.

Snow Guards for Aluform Systeme Standing Seam Roof Panels

This guide covers FALZRIPP 50/333, FALZRIPP 50/429, FALZRIPP 65/305, FALZRIPP 65/333, FALZRIPP 65/400, and FALZRIPP 65/500. Although their seam heights and coverage widths vary, the profiles share the same compatibility shown below.

Standing seam warning: Do not install screw-down snow guards through concealed-fastener FALZRIPP panels. Use compatible RCT clamp-based systems, or adhesive-mounted polycarbonate guards where the panel surface provides a flat and suitable bonding area.

Do you need more information about our compatible snow guards for Aluform Systeme standing-seam roof panels? Check out our full blog here: Snow Guards for Aluform Systeme Standing Seam Metal Roof Panels.

  FALZRIPP 50/333 Profile FALZRIPP 50/429 Profile FALZRIPP 65/305 Profile FALZRIPP 65/333 Profile FALZRIPP 65/400 Profile FALZRIPP 65/500 Profile
Icejax I polycarbonate snow guard
Icejax I
*YES *YES *YES *YES *YES *YES
Icejax II polycarbonate snow guard
Icejax II
*YES *YES *YES *YES *YES *YES
Ecojax polycarbonate snow guard
Ecojax
*YES *YES *YES *YES *YES *YES
SnoBlox Deuce polycarbonate snow guard
SnoBlox Deuce
*YES *YES *YES *YES *YES *YES
SnoBlox Ace polycarbonate snow guard
SnoBlox Ace
*YES *YES *YES *YES *YES *YES
Snojax II polycarbonate snow guard
Snojax II
*YES *YES *YES *YES *YES *YES
SnowBreaker snow guard
SnowBreaker
*YES *YES *YES *YES *YES *YES
SnoBar Standing Seam snow rail
SnoBar Standing Seam
NO NO NO NO NO NO
ColorBar Standing Seam snow rail
ColorBar Standing Seam
NO NO NO NO NO NO
SnoBar RCB-3 snow rail
SnoBar RCB-3
YES YES YES YES YES YES
ColorBar RCB-3 snow rail
ColorBar RCB-3
YES YES YES YES YES YES
SnoBar 2-Bar snow rail
SnoBar 2-Bar
YES YES YES YES YES YES
ColorBar 2-Bar snow rail
ColorBar 2-Bar
YES YES YES YES YES YES
SnoCleat RC clamp-on snow guard
SnoCleat RC
NO NO NO NO NO NO
SnoCleat RCT clamp-on snow guard
SnoCleat RCT
YES YES YES YES YES YES

All six FALZRIPP profiles share the compatibility shown above. Ecojax appears directly above SnoBlox Deuce because both polycarbonate snow guards fit the same Aluform Systeme panels.

Panel striations may require a thicker application of SureBond SB-190 to achieve full contact and reduce moisture paths beneath adhesive-mounted guards. Allow approximately 28 days at 50°F or warmer for the adhesive to cure fully.

Test-fit RCT clamps before placing a complete order, especially on softer aluminum panels. For ground snow loads above 45 psf, consider a professionally designed rail layout with the number of rows determined by project conditions.

Aluform Systeme Snow Guard Buying Checklist

  • Confirm the exact Aluform Systeme panel name before choosing any product.
  • Determine whether the roof is straight or curved. Adhesive guards require a flat mounting surface.
  • Verify the attachment method: adhesive-mounted polycarbonate or a compatible RoofClamp RCT-based product.
  • Check the ground snow load. Individual guards are generally best suited to lighter applications, while heavier loads often require rail systems.
  • Request a layout instead of protecting only isolated areas such as entrances, chimneys, or equipment.
  • Order samples or single units when you need a test fit. SnoBlox-Snojax products and components are available with no minimum order requirement.

Need Help Identifying Your Aluform Systeme Panel?

If you are not sure which Aluform Systeme panel you have, carefully compare the panel profile, review the two detailed Aluform Systeme blog posts linked above, and order a single test-fit unit before committing to a full project. For project-specific help, contact SnoBlox-Snojax at support@snojax.com or call 1-800-766-5291.

Do you have a metal roof from a different manufacturer?

Visit our "Snow Guard Compatibility by Roof Manufacturer" resource page for detailed information on which snow guards and snow retention systems are compatible with your metal roof.

Compatibility Guidance Note

SnoBlox-Snojax bases the compatibility information presented in this guide on product testing and field experience with Aluform Systeme metal roof panel profiles. Panel manufacturers periodically update profile specifications, and individual project variables, such as seam condition, coating type, and installation method, can affect outcomes. Customers are encouraged to confirm current panel specifications directly with Aluform Systeme and to contact SnoBlox-Snojax with project-specific questions before ordering.

Snow Guards for Aluform Systeme Metal Roofing Panels – Compatibility & Installation FAQ

Aluform Systeme FALZRIPP panels are compatible with selected adhesive-mounted polycarbonate snow guards and non-penetrating systems that use RoofClamp RCT. Compatible options include Icejax I, Icejax II, Ecojax, SnoBlox Deuce, SnoBlox Ace, Snojax II, SnowBreaker, SnoCleat RCT, RCB-3 rail systems, and 2-bar rail systems.
This guide covers the FALZRIPP 50/333, FALZRIPP 50/429, FALZRIPP 65/305, FALZRIPP 65/333, FALZRIPP 65/400, and FALZRIPP 65/500 standing seam profiles.
Yes. Ecojax fits the same Aluform Systeme FALZRIPP profiles as the SnoBlox Deuce. Both are adhesive-mounted polycarbonate snow guards and require a suitable flat bonding surface.
No. Screw-down snow guards should not penetrate concealed-fastener FALZRIPP standing seam panels. Use a compatible adhesive-mounted product or a non-penetrating clamp-on system.
No. The bulb-shaped FALZRIPP seams are not compatible with standard SnoBar clamps or RoofClamp RC products. Compatible rail systems must use RoofClamp RCT in an RCB-3 or 2-bar configuration.
SnoCleat RCT is the compatible individual clamp-on snow guard shown for the FALZRIPP profiles in this guide. SnoCleat RC is not compatible with these bulb-shaped seams.
Adhesive-mounted pad-style snow guards are not recommended when panel curvature prevents the guard’s base from sitting completely flat. Consider a compatible clamp-on snow guard or rail system for curved roof applications.
Yes. Panel striations may require a thicker application of SureBond SB-190 to fill small gaps and create proper contact between the snow guard and roof surface. Correct surface preparation and adhesive application are essential.
SureBond SB-190 requires approximately 28 days at temperatures of 50°F or warmer to cure fully. Temperatures below 50°F pause or slow the curing process and extend the installation timeline.
Yes. Test-fitting is recommended before placing a complete order, especially on aluminum panels. Panel dimensions, seam condition, material softness, and installation variables can affect compatibility.
They may be. Aluminum is softer than steel, so additional rows, closer spacing, or other project-specific measures may be necessary. Consider the roof slope, panel width, run length, seam spacing, and ground snow load.
Rail systems are generally recommended for roofs with ground snow loads above 45 psf and for projects requiring more substantial snow retention. The correct number of rows depends on the roof dimensions, slope, panel spacing, and local snow load.
No. Snow guards and rails should extend across the entire roof area being protected. Installing them only above entrances, HVAC equipment, chimneys, or other isolated areas can concentrate snow loads and increase the risk of system failure.
Compare the panel’s seam height, coverage width, and profile shape with Aluform Systeme documentation. If compatibility remains uncertain, order a single product or clamp for a test fit before purchasing the complete system.
Contact SnoBlox-Snojax at support@snojax.com or call 1-800-766-5291 for product selection and layout assistance.