null Skip to main content

Economical 6 Foot SnoBar and ColorBar Snow Rail Kits

See Now

Snow Guards for Ash and Lacy Metal Roofing

Snow guards for Ash & Lacy roofing panels help manage the sudden movement of rooftop snow and ice above entrances, walkways, parking areas, landscaping, equipment, and other places where sliding accumulation may create safety concerns or property damage. Selecting the correct SnoBlox-Snojax solution depends on the exact Ash & Lacy panel profile, seam geometry, roof material, and project conditions.

Compatible Ash & Lacy snow retention options may include adhesive-mounted polycarbonate guards, RCB-3 rail systems, 2-bar rail systems, and the clamp-on SnoCleat RCT, depending on panel shape, roof configuration, and material.
  • Ash & Lacy Standing Seam panels feature a bulb-shaped rib that requires compatible RCT-based clamp-on products.
  • Adhesive-mounted polycarbonate snow guards may be used on flat panel configurations with a suitable bonding surface.
  • Curved or radiused panels should use compatible clamp-on rail systems or SnoCleat products instead of individual adhesive-mounted guards.
  • Standard SnoBar and ColorBar standing seam clamps and the SnoCleat RC are not compatible with this seam profile.
  • Final product selection should consider roof slope, panel width, run length, roof material, striations, ground snow load, and full-roof layout requirements.
Important: Do not select snow guards based on appearance alone. Ash & Lacy panels may be manufactured from aluminum, steel, copper, or zinc, and the correct attachment method must account for the roof material, seam shape, and panel configuration. Individual adhesive-mounted snow guards require a flat mounting surface and are not appropriate for curved panels. Incompatible clamps or an incorrect installation method can reduce holding strength or damage the roof system.

⚡ Ash & Lacy Primary Quick Selection Guide

Use this section for fast profile-level direction. Confirm the exact product fit in the full compatibility chart below.

  • Flat Standing Seam configurations: May accept adhesive-mounted polycarbonate guards, including IceJax I, IceJax II, Ecojax, SnoBlox Deuce, SnoBlox Ace, SnoJax II, and SnowBreaker, when the panel material, finish, and flat bonding surface are suitable for SureBond SB-190. 
  • Bulb-shaped seam: Compatible clamp-on choices include RCB-3 SnoBar/ColorBar, 2-Bar SnoBar/ColorBar, and SnoCleat RCT, subject to a successful test fit.
  • Curved or radiused panels: Use compatible clamp-on bar systems or SnoCleat RCT. Individual glue-down polycarbonate guards require a flat surface and should not be used on curved configurations.
  • Clamp warning: Standard SnoBar/ColorBar standing seam clamps and SnoCleat RC do not fit this bulb-shaped seam.

About Ash & Lacy Roofing Systems

Ash & Lacy traces its history to 1857, when Joseph Ash founded his business, followed by his partnership with John Pierce Lacy in 1864. Over more than 150 years, the company expanded its engineering and manufacturing capabilities across roofing, facade, construction, automotive, acoustic, and audio markets. Its modern building systems include engineered roofing and cladding products used on a wide range of architectural projects.

Ash & Lacy Steel Products was formed in 1970, and the company continued introducing building solutions and specialized systems in the following decades. Ash & Lacy Building Systems was established in 1989, and the business later expanded its manufacturing presence throughout the United Kingdom while adding complementary product lines and capabilities.

Snow Retention Solutions for Ash & Lacy Roofing

Ash & Lacy Standing Seam roofing requires snow retention products matched to its distinctive bulb-shaped seam and the specific panel configuration. Flat installations may accept adhesive-mounted polycarbonate guards when the pan provides a suitable bonding area. Compatible clamp-on systems use RCT-style clamps designed for this seam geometry.

See our complete selection of snow guards for metal roofs and use the chart below to identify compatible SnoBlox-Snojax products for Ash & Lacy Standing Seam panels. “YES” indicates a listed fit when the panel material, finish, bonding surface, and project conditions are suitable, while “NO” means the product is not shown as compatible. “*YES” means a sample clamp should be test-fitted before ordering the complete system.

Snow Guards for Ash & Lacy Standing Seam Roof Panels

Ash & Lacy's Standing Seam system has served the United Kingdom construction market for more than 20 years. Standard panel widths include 300 mm (approximately 11.81 inches) and 400 mm (approximately 15.75 inches), with a 50 mm (approximately 1.97-inch) seam height. Panels can be formed in lengths up to 30 meters (approximately 98.4 feet), helping minimize end laps.

The system is available in several materials and thicknesses, including 0.9 mm and 1.2 mm aluminum, 0.7 mm and 0.9 mm steel, 0.6 mm and 0.7 mm copper, and 0.7 mm and 0.8 mm zinc. It may be installed on slopes as low as 1.5 degrees and is available for both straight and curved architectural applications.

Standing seam warning: Do not install screw-down snow guards through Ash & Lacy Standing Seam panels. Use compatible non-penetrating clamp-on products where the seam accepts them, or adhesive-mounted guards when a flat and suitable bonding surface is available.

Do you need more information about our compatible snow guards for Ash & Lacy standing-seam roof panels? Read our full blog here: Snow Guards for Ash & Lacy Standing Seam Metal Roof Panels.

Panel striations may require a thicker bead of SureBond SB-190 to fill minor gaps and help prevent moisture paths beneath adhesive-mounted guards. These products need a flat bonding surface and should not be installed on curved panel configurations.

The bulb-shaped seam accepts compatible RCT-based clamps. Test-fit a clamp sample before placing a complete order. Softer aluminum and copper panels may require additional rows of clamp-on snow retention to account for lower panel strength.

For rail systems installed above pedestrian or parking areas, IceStopper attachments are recommended to help manage snow and ice beneath the rail.

Ash & Lacy Snow Guard Buying Checklist

  • Confirm the Ash & Lacy Standing Seam profile before selecting a product.
  • Determine whether the roof is flat or curved. Adhesive-mounted guards require a flat bonding surface.
  • Verify the roof material. Ash & Lacy panels may be aluminum, steel, copper, or zinc, and material strength can influence system design.
  • Test-fit clamp-on products. The bulb-shaped seam requires compatible RCT-based clamps.
  • Check ground snow load. Individual glue-down guards are generally best suited for lighter snow-load applications. Loads above 45 psf typically require a rail system.
  • Request a layout instead of protecting only isolated locations such as doors, chimneys, or rooftop equipment.
  • Order samples or individual components when a test fit is needed. SnoBlox-Snojax products and components are available without a minimum order requirement.

Need Help Identifying Your Ash & Lacy Panel?

If you are not sure which Ash & Lacy panel you have, carefully compare the panel profile, review the detailed Ash & Lacy standing seam blog linked above, and order a single test-fit unit before committing to a full project. For project-specific help, contact SnoBlox-Snojax at support@snojax.com or call 1-800-766-5291.

Do you have a metal roof from a different manufacturer?

Visit our "Snow Guard Compatibility by Roof Manufacturer" resource page for detailed information on which snow guards and snow retention systems are compatible with your metal roof.

Compatibility Guidance Note

SnoBlox-Snojax bases the compatibility information presented in this guide on product testing and field experience with Ash & Lacy metal roof panel profiles. Panel manufacturers periodically update profile specifications, and individual project variables, such as seam condition, coating type, and installation method, can affect outcomes. Customers are encouraged to confirm current panel specifications directly with Ash & Lacy and to contact SnoBlox-Snojax with project-specific questions before ordering.

Snow Guards for Ash & Lacy Metal Roofing Panels – Compatibility & Installation FAQ

Compatible options include IceJax I, IceJax II, Ecojax, SnoBlox Deuce, SnoBlox Ace, SnoJax II, and SnowBreaker on suitable flat panel configurations. Compatible clamp-on options include RCB-3 SnoBar and ColorBar systems, 2-Bar SnoBar and ColorBar systems, and SnoCleat RCT.
Yes. Ecojax fits the same Ash & Lacy Standing Seam profile as the SnoBlox Deuce. Both are adhesive-mounted polycarbonate snow guards and require a suitable flat bonding surface.
No. Individual adhesive-mounted snow guards require a flat surface for proper bonding. Use compatible clamp-on rail systems or SnoCleat RCT on curved or radiused Ash & Lacy panels.
The RoofClamp RCT is the compatible clamp for Ash & Lacy's bulb-shaped seam. It may be used with RCB-3 and 2-Bar SnoBar or ColorBar systems. Always test-fit a clamp sample before ordering a complete system.
No. Standard SnoBar and ColorBar standing-seam clamps are not compatible with the Ash & Lacy bulb-shaped seam. RCT-based clamp systems are required.
No. SnoCleat RC is not compatible with this seam profile. SnoCleat RCT is the appropriate clamp-on SnoCleat option, subject to a successful test fit.
No. Do not fasten screw-down snow guards and rails through concealed-fastener standing-seam panels. Use compatible non-penetrating clamp-on systems or adhesive-mounted guards where appropriate.
Yes. Striated panels may require a thicker application of SureBond SB-190 to fill small gaps and reduce potential moisture paths beneath the snow guard.
Adhesive-mounted polycarbonate snow guards are not recommended for copper roofing. Contact SnoBlox-Snojax for help selecting an appropriate clamp-on system.
SureBond SB-190 requires approximately 28 days at temperatures of 50°F or higher to fully cure. Schedule installation when suitable temperatures can be maintained throughout the curing period.
They may. Aluminum and copper are softer than steel, so additional rows of clamp-on snow retention may be necessary to account for lower panel strength.
Individual adhesive-mounted snow guards are generally best suited for lighter snow-load applications. A professionally designed rail system is typically recommended when the ground snow load exceeds 45 psf.
No. Snow retention should be designed for the entire roof area, not just isolated locations. Concentrating snow guards in a small area can overload the system and the roof panels.
Yes. IceStopper attachments are recommended when rail systems are installed above entrances, walkways, parking areas, or other locations where snow and ice may pass beneath the rail.
Yes. Order a single compatible clamp or component and confirm it fits the actual Ash & Lacy seam before purchasing the complete system. SnoBlox-Snojax products are available without a minimum order requirement.
A project layout generally requires the panel width, seam spacing, roof slope, eave length, roof run, roof material, panel configuration, and local ground snow load. These details help determine the appropriate product, number of rows, and spacing pattern.