null Skip to main content

Snow Guards for Inland Buildings

Snow guards for Inland Building Systems roofing panels help manage snow and ice on roofs above walkways, doors, loading zones, parking areas, landscaping, and equipment. Choose a SnoBlox-Snojax system by identifying whether the Inland Building Systems roof has a standing-seam concealed-fastener system or an exposed-fastener panel, and confirming the specific panel geometry.

Compatible Inland Building Systems snow retention options may include adhesive-mounted polycarbonate guards, screw-fastened guards, SnowCatcher products, PBR-style rail systems, non-penetrating clamp-on rail assemblies, RCB-3 rail systems, 2-bar rail systems, and clamp-on SnoCleat products, depending on the panel geometry.
  • Inland Building Systems standing-seam and exposed-fastener panels require different snow-retention attachment methods.
  • Standing seam panels should use compatible clamp-on systems or adhesive-mounted guards, not screw-down attachments.
  • Exposed-fastener panels may accept compatible adhesive-mounted guards, screw-down guards such as SnowCatcher and SnoCleat PBR, or SnoBar PBR and ColorBar PBR rail systems, depending on panel geometry and available mounting area.
  • Inland Building Systems TS-324 and VS-216 profiles show broad compatibility with adhesive and clamp-on options.
  • Final product selection should account for roof slope, panel width, snow load, run length, roof material, panel striations, and full-roof layout requirements.
Important: Do not choose snow guards based only on appearance. A guard or rail system that works on one Inland Building Systems profile may not work on another. Clamp-on systems are intended only for compatible standing-seam profiles. In contrast, exposed-fastener panels may require adhesive bonding, mechanical fastening, PBR brackets, or other panel-specific mounting methods. An incorrect selection can reduce holding strength, increase leak risk, or cause premature system failure.

⚡ Inland Building Systems Primary Quick Selection Guide

Use this section for fast profile-level direction. Confirm the exact product fit in the full compatibility charts below.

  • TS-324 panels: Compatible with adhesive-mounted polycarbonate guards, SnoBar/ColorBar standing seam rails, RCB-3 systems, 2-bar rails, and SnoCleat RC/RCT.
  • VS-216 panels: Support the listed adhesive-mounted polycarbonate guards and compatible non-penetrating clamp-on systems.
  • PBR exposed-fastener panels: Compatible with selected polycarbonate guards, SnowCatcher, SnoCleat PBR, SnoBar PBR, and ColorBar PBR when installed according to project requirements.
  • Standing seam warning: Do not fasten screw-down snow guards through concealed-fastener standing seam panels.

About Inland Building Systems Roofing Systems

Inland Building Systems supplies engineered metal building systems. The company traces its history back to Inland Steel, and its roofing range includes TS-324 and VS-216 standing seam systems, along with exposed-fastener PBR panels. Match snow retention products to the installed panel profile and attachment method.

Snow Retention Solutions for Inland Building Systems Roofing

Inland Building Systems standing seam and exposed-fastener panels do not use the same snow-retention attachment method. Standing seam roofs typically require non-penetrating clamp-on systems when the seam geometry allows it, or adhesive-mounted guards when the panel pan provides a suitable bonding surface. Exposed-fastener panels may accept screw-down products when attached through the low flats and into adequate structure.

See our full range of snow guards for metal roofs and use the charts below to confirm which SnoBlox-Snojax products fit each Inland Building Systems panel. “YES” indicates the product is shown as a fit for that panel. “NO” means it is not shown as compatible for that profile.

Snow Guards for Inland Building Systems Standing Seam Roof Panels

The TS-324 system has a 24-inch panel width and 3-inch seam height. The VS-216 system uses a 16-inch panel width. Both profiles accept the adhesive-mounted polycarbonate guards and compatible clamp-on systems shown below. Test-fit clamps on the actual seam before placing a full order.

Standing seam warning: Do not install screw-down snow guards through concealed-fastener standing-seam roof panels. Use compatible clamp-on products where the seam accepts them, or adhesive-mounted guards where a flat bonding surface is available.

Do you need more information about our compatible snow guards for Inland Building Systems standing-seam roof panels? Check out our full blog here: Snow Guards for Standing Seam Metal Roof Panels by Inland Building Systems.

  TS-324 Panel VS-216 Panel
IceJax I
IceJax I
YES YES
IceJax II
IceJax II
YES YES
EcoJax
EcoJax
YES YES
SnoBlox Deuce
SnoBlox Deuce
YES YES
SnoBlox Ace
SnoBlox Ace
YES YES
SnoJax II
SnoJax II
YES YES
SnowBreaker
SnowBreaker
YES YES
SnoBar Standing Seam
SnoBar Standing Seam
YES YES
ColorBar Standing Seam
ColorBar Standing Seam
YES YES
SnoBar RCB-3
SnoBar RCB-3
YES YES
ColorBar RCB-3
ColorBar RCB-3
YES YES
2 Bar SnoBar
2 Bar SnoBar
YES YES
2 Bar ColorBar
2 Bar ColorBar
YES YES
SnoCleat RC
SnoCleat RC
YES YES
SnoCleat RCT
SnoCleat RCT
YES YES

TS-324 and VS-216 profiles offer broad standing-seam compatibility because they accept many adhesive-mounted guards and compatible clamp-on snow-retention systems.

EcoJax is a polycarbonate snow guard for suitable flat mounting areas. Confirm roof material, finish compatibility, and adhesive requirements before installation.

Striations may require additional adhesive to fill gaps beneath the guard. Surebond SB-190 requires approximately 28 days at temperatures of at least 50°F to cure. Do not glue guards to copper or install flat-base guards on curved surfaces. Select IceStoppers to suit the rail clearance and panel spacing when the project requires ice management.

Snow Guards for Inland Building Systems Exposed Fastener Roof Panels

This guide focuses on Inland Building Systems exposed-fastener compatibility for the PBR profile. The PBR has a 36-inch coverage width, major ribs spaced at 12-inch intervals, and a rib height of about 1.25 inches. Its low-flat areas and rib layout allow several individual snow guard and rail-style snow retention options when the system is attached correctly.

Exposed fastener reminder: When screw-down snow guards or rails are compatible, they should be attached through the low flats of the panel and into adequate structure. Do not install individual snow guards on the high ribs. Follow the specified bracket attachment details for rail systems.

Need more information about our compatible snow guards for Inland Building Systems exposed-fastener roof panels? Check out our full blog here: Snow Guards for Exposed Fastener Metal Roof Panels by Inland Building Systems.

Inland Building Systems PBR accepts compatible polycarbonate snow guards, including EcoJax and SnoBlox Deuce, mechanically attached metal guards such as SnowCatcher and SnoCleat PBR, and SnoBar PBR and ColorBar PBR rail systems.

SnoCleat 2.67, SnoBar 2.67, and ColorBar 2.67 do not work with the Inland Building Systems PBR profile because these systems only work with 2.67-inch corrugated panel geometry.

For screw-down installations, fasteners must engage suitable structure beneath the roof panel. For adhesive-mounted polycarbonate guards, allow approximately 28 days at temperatures of at least 50°F for Surebond SB-190 to cure, and avoid copper roofing applications. Do not use SB-190 to attach metal pad-style guards.

Inland Building Systems Snow Guard Buying Checklist

  • Confirm the exact Inland Building Systems panel name before choosing any product.
  • Identify the roof type: Determine whether you have a concealed-fastener standing seam system or an exposed-fastener PBR panel.
  • Verify the attachment method: Choose compatible adhesive-mounted guards, screw-down guards, clamp-on systems, or PBR-mounted rail systems for the specific panel.
  • Check ground snow load. Product selection and layout depend on snow load, roof slope, slope length, panel geometry, and attachment capacity. Higher loads may require rail systems or additional rows.
  • Request a layout rather than installing only in isolated areas such as doors, chimneys, or HVAC equipment.
  • Order samples or single units when you need a test fit. SnoBlox-Snojax products and components are available with no minimum order requirement.

Need Help Identifying Your Inland Building Systems Panel?

If you are not sure which Inland Building Systems panel you have, carefully compare the panel profile, review the two detailed Inland Building Systems blog posts linked above, and order a single test-fit unit before committing to a full project. For project-specific help, contact SnoBlox-Snojax at support@snojax.com or call 1-800-766-5291.

Do you have a metal roof from a different manufacturer?

Visit our "Snow Guard Compatibility by Roof Manufacturer" resource page for detailed information on which snow guards and snow retention systems are compatible with your metal roof.

Compatibility Guidance Note

SnoBlox-Snojax bases the compatibility information presented in this guide on product testing and field experience with Inland Building Systems metal roof panel profiles. Panel manufacturers periodically update profile specifications, and individual project variables, such as seam condition, coating type, and installation method, can affect outcomes. Customers should confirm current panel specifications directly with Inland Building Systems and contact SnoBlox-Snojax with project-specific questions before ordering. 

Snow Guards for Inland Building Systems Metal Roofing Panels – Compatibility & Installation FAQ

Compatible products depend on the panel profile, roof material, and attachment method. TS-324 and VS-216 standing seam panels accept suitable adhesive-mounted polycarbonate guards and compatible clamp-on systems. PBR exposed fastener panels accept selected adhesive-mounted guards, screw-down guards, and mechanically attached rail systems.
No. Never screw snow guards through Inland Building Systems standing seam panels. Use compatible non-penetrating clamp-on systems or adhesive-mounted guards where the roof material, finish, and mounting surface allow them.
TS-324 panels accept suitable adhesive-mounted polycarbonate guards, including EcoJax, SnoBlox Deuce, IceJax I, IceJax II, SnoBlox Ace, and SnoJax II. Compatible clamp-on options include SnoCleat RC and RCT, SnoBar and ColorBar standing seam rails, RCB-3 systems, and 2-bar systems. Confirm the actual seam configuration and test-fit mounting hardware before ordering.

VS-216 panels accept suitable adhesive-mounted polycarbonate guards, including EcoJax, SnoBlox Deuce, IceJax I, IceJax II, SnoBlox Ace, and SnoJax II, along with compatible clamp-on SnoCleat RC and RCT products. SnoBar and ColorBar standing seam rails, RCB-3 systems, and 2-bar systems also provide options when the mounting hardware fits the installed seam.

Yes. Test-fit a sample clamp on the actual roof seam before placing a full order. Confirm that the clamp fits correctly and allows you to achieve the required installation torque. Panel names alone do not confirm hardware fit.
PBR panels accept suitable polycarbonate guards, including EcoJax, SnoBlox Deuce, IceJax I, IceJax II, SnoBlox Ace, and SnoJax II. Other compatible options include screw-mounted SnoJax I, SnowBreaker, mechanically attached SnowCatcher metal guards, SnoCleat PBR, SnoBar PBR, and ColorBar PBR. Follow each product’s attachment instructions.
No. These products fit 2.67-inch corrugated panel geometry. Inland Building Systems PBR requires compatible PBR products or suitable individual guards that fit the available mounting surface.
Install individual screw-down guards through the panel’s low flats and into suitable underlying structure. Never mount individual guards on the high ribs or rely on the roof sheet alone for attachment strength. Follow the specified mounting details for rail brackets.

Surebond SB-190 requires about 28 days at temperatures of at least 50°F to fully cure. Schedule adhesive installation around a suitable warm-weather window. Colder conditions extend curing time, so allow the adhesive to cure before snow loads reach the guards.

No. Adhesive-mounted polycarbonate guards require a suitable flat bonding area and a compatible roof material and finish. Striations may require additional adhesive to fill gaps beneath the guard. Do not glue guards directly to copper. Do not install flat-base guards on curved surfaces or use SB-190 to attach metal pad-style guards.

SnoBlox-Snojax does not recommend isolated installations above doors, walkways, or equipment. These small areas can collect loads from the roof above and overload the system. Request a full-roof layout that accounts for roof slope, snow load, panel spacing, and slope length.
Start by confirming the panel profile, roof material, slope, slope length, panel width, and project ground snow load. Contact SnoBlox-Snojax for a project-specific layout and product recommendation. A complete system may require multiple rows of guards or rails, along with IceStoppers where the rail clearance and project conditions call for additional ice management.